CANTHERM
  1/2" Disc Bimetal Cutouts  
 

< Back to Bimetal Cutouts

 Temperature Regulators / Temperature Limiters     Download PDF



R27, R28, R29
- Up to 100,000 cycles
- Various terminals on-hand
- Small tolerances and hysteresis available

- Response temperatures from 0°C up to 260°C

Applications Houshold appliances, Electronics, Machinery

 > Technical Data (R27  R28   R29)
ratings \ control type
R28 R27 R29
11EN 03EN 52N 60EN1)
05EN
15N
23EN
function automoatic manual
version normally closed / normally open normally closed
VDE
rated current at 250 Vac (cos 0,95)
16 A
10 A
10 A
10 A
16 A
16 A
16 A
switching cycles
10,000
100,000
100,000
100,000
6,000
6,000
3,000
temperature range Ta (steps in 5 K)
0 °C ... 150 °C
0 °C ... 150 °C
0 °C ... 230°C2)
0 °C ... 150 °C 0 °C ... 150 °C 0 °C ... 250°C 0 °C ... 150 °C
UL
rated current at 250 Vac (cos 0,95)
15A/10A
15A/10A
15A/10A
-

15A/10A

16A/16A
15A/10A
switching cycles
100,000
100,000
100,000
-
6,000 6,000 6,000
temperature range Ta ( steps in 5 K )
0 °C ... 150 °C
0 °C ... 150 °C
0 °C ... 230°C
-
0 °C ... 150 °C 0 °C ... 250 °C 0 °C ... 150 °C
tolerances   TA <100°C: ± 3 K / TA >100°C: ± 4 K / TA >140°C: ± 5 K
contact resistance   < 30 mΩ
hysteresis / reset temperature   TA <100°C: 10 K ± 4 K / TA >100°C: 15 K ± 5 K / TA >140°C: 20 K ± 5 K customer-specific
degrees of protection provided by enclosures ( EN 60529 ) IPOO (R28 60EN IP54)
suitable for use in protection class I, II
approval VDE/ENEC EN versions have VDE approvals: EN 60730-1 / -2-9 plus UL/CSA listings
UL N versions have UL and CSA listing: UL 873
CSA N versions have UL and CSA listing: C22.2 No. 24 3)
1) not approved
2) type R28 55H up to 260°C
3) different approved ratings


 > Standard Types
type
nc no
code
illustration
drawing
dimensions (mm)
tech description approvals
R28 11EN
1 3 11EN=Plastic
10EN=ceramic

dielectric strength
2,000 Vac
terminals 6.3 x 0.8
housing thermosetting plastic 9mm, moving bracket, small
cap aluminum
VDE, UL, CSA
R28 03EN
1 3 standard

dielectric strength
2,000 Vac
terminals 6.3 x 0.8,
housing thermosetting
plastic 12mm,
moving bracket small,
cap aluminium
VDE, UL, CSA
R28 52N
1 3 plastic<170ºC or
ceramic>170ºC

dielectric strength 2,000 Vac
terminals 6.3 x 0.8,
housing ceramic 12mm,
moving bracket small,
cap aluminium
VDE, UL, CSA

R27 05EN

1   manual

dielectric strength 1,800 Vac




terminals 6.3 x 0.8,
housing thermosetting plastic, moving bracket small,
cap aluminium,
reset pin
VDE, UL, CSA
R27 15N
1   manual

dielectric strength 1,800 Vac
terminals 6.3 x 0.8,
housing ceramic,
moving bracket small,
cap aluminium,
reset pin ceramic
VDE, UL, CSA
R29 23EN
1   manual

dielectric strength 2,000 Vac
terminals 6.3 x 0.8,
housing thermosetting plastic,
moving bracket small,
cap aluminium,
reset pin
VDE, UL, cUL
R28 60EN
1 3 tight against humidity
dielectric strength
1,800 Vac
lead wire 1.25mm2,
housing thermosetting plastic,
fix bracket,
cap aluminium,
degree of protection IP54
VDE

 

 > Brackets
Code
used in type
illustration
drawing
dimensions (mm)
tech specification approvals
4
R27, R28, R29 aluminum loose bracket, small
use with T cap
VDE, UL, CSA
3
R27, R28, R29

stainless steel loose bracket
use with V cap

VDE, UL, CSA
S
R27, R28, R29 stud of
M5 x 6 brass, SW17
(S5 shown, other variations
available)
VDE, UL, CSA
B (+ angle)
R27, R28, R29 fix bracket
possible angles:
0 / 45 / 90 / 135 deg
VDE, UL, CSA

 

 > Terminals
Code
used in type
illustration
drawing
dimensions (mm)
tech specification approvals
brass: 03 (0°)
brass: 09 (45°)
brass: 04 (90°)
steel: 93 (0°)
steel: 94 (90°)
R27, R28, R29 terminals 6.3 x 0.8
brass nickel plated up to
TA max. 150°C
>150°C steel nickel plated
also available: angle 45 / 90 deg
VDE, UL,
CSA
brass: 05 (0°)
brass: 10 (45°)
brass: 06 (90°)
steel: 95 (0°)
steel: 96 (90°)
R27, R28, R29

terminals 4.8 x 0.5
brass nickel plated up to
TA max. 150°C
>150°C steel nickel plated
also available: angle 45 / 90 deg

VDE, UL,
CSA
00
R27, R28 solder terminals VDE, UL,
CSA
SA
R27, R28 PCB terminals
solder terminals
VDE, UL,
CSA
41 (0°)
42 (90°)
R27, R28, R29 solder terminals,
nickel plated,
also available: angle 90 deg
VDE, UL,
CSA
brass: 45 (0°)
brass: 46 (90°)
R27, R28, R29 terminals 4.8 x 0.8
brass nickel plated up to
TA max.150°C
also available: angle 90 deg
VDE, UL,
CSA


 > Caps

Standard cap, material aluminium (code T)
Use with bracket #4

 

 

Stainless steel cap (code V) for large loose bracket #3 or fixed bracket B +angle

Deviations from standard controls (caps, terminals, fixings) on request.

Especially for electronic applications with voltage 6…120 Vac / 6…30 Vdc and current 10…100 mA, there are switches with crossbar- contacts available. (code P)

Controls as single operation device (SOD) up to 150°C and reset temperature -35°C are available (type 81ES).


 > Ordering & Marking Example
Cantherm Ordering Example  R2803EN15T03450+/-340+/-4 ]
R28 03 E N 1 5 T 03 4 50+/-3 40+/-4
type base type European version type of contact (N normal contact / P low current) contact execution (1 normally closed / 3 normally open) housing plastic 1=UL/CSA; 5=UL/CSA/VDE (Use w/ E) 2=ceramic cap code terminal code fixing code response temperature reset temperature

Marking
A100 norm. closed (B norm. open) response temperature
03EN
XXXX type manufacture code
XXXX
date of manufacture

 
CANTHERM
(800) 561-7207 | sales@cantherm.com