CANTHERM
  Heater Protection  
 

 Auto Reset & PTCR Protector -
Both Temp. and Current Sensitive
 

A40, A41, A60, A61, A80, A81, A82,
A83, A92, A93, D44, D64, D83, D84 and D94


CURRENT AND TEMPERATURE CUTOUT
For automatic current and temperature protection -
Types A40, A41 and D44.

CURRENT AND TEMPERATURE LIMITER
Manual reset device for automatic current and temperature protection -
Types A60, A61 and D64

CURRENT AND TEMPERATURE CUTOUT
Electrical self-hold device for automatic current and temperature protection -
Types A80, A81, A82, A83, A92, A93, D83, D84 and D94

INSTALLATION
Owing to the small size and minimal weight of the basic model without
mounting lugs, it is possible to attach the cutout in-line with two conductors without any additional fastening. Connector styles available: push-on, solder tags, rivet, screw or crimp.

Thermal and current-sensitive cutouts with the electrical self-hold feature switch off when reaching the preset temperature or current level. The switch is then held open by a heating resistor (PTC) in parallel - the cutout will not automatically reset while voltage is applied. It will reset when voltage is removed (ie the appliance concerned is disconnected and the cutout has cooled down).

PDF A40, A41, A60, A61, A80, A81, A82, A83, A92, A93, D44, D64, D83, D84, D94
   > PDF Tech Info, Schematics and More

Applications Temperature monitoring/ regulation/ limiting and current limiting in electrical equipment. EXAMPLES  Driers, Cooking appliances, Radiators, Motors, Transformers

 > Technical Data
Type
A40 / A41
D 44
A60 / A61
D 64
A80 / A81
D 84
A82 / A83
D 83
A92 / A93
D 94
Function
Auto reset
manual reset
electrical self-hold
Nominal voltage 50-60 Hz
250 V
250 V
110-130 V
12-30 V
Current rating cos = 1,0
Current rating cos = 0,6
2-13 A
2-16 A
2-16 A
2-10 A
Max.switching capacity
at nominal voltage and cos = 1,0
20 A
20 A
20 A
16 A
at other voltages, max. load varies with each version
120V~
250V~
400V~
Specific construction (manufacturer's letter D-V) will depend on customer's application and specified values.
D
12,0 A
10,0 A
5,0 A
G
12,0 A
10,0 A
5,0 A
J
19,2 A
16,0 A
8,0 A
K
8,4 A
7,0 A
3,5 A
L
15,6 A
13,0 A
6,5 A
M
19,2 A
16,0 A
8,0 A
P
19,2 A
16,0 A
8,0 A
R
6,0 A
5,0 A
2,5 A
V
19,2 A
16,0 A
8,0 A
Nominal temperature range in 5-°C steps
70°C to 160°C
Contact arrangement normaly closed
Contact resistance
</= 250 m
Tolerance
as specified
Response time
up to 60 s

 

A40
 PDF
  A40, A41, A60, A61, A80, A81, A82,
  A83, A92, A93, D44, D64, D83, D84, D94

    > All Tech Info, Schematics and More.
 

 

CANTHERM
CANADA (800) 561-7207 | sales@cantherm.com
USA (330) 966-3796 | rmurk@cantherm.com
© 2008, Canadian Thermostats & Control Devices Ltd.