CANTHERM
  Heater Protection  
 

 Enclosed Radial Lead Thermostats    PDF

D10, D20, D30, D40

Applications Household appliances, Electronics, Fan Heaters, Automotive Industry

Benefits
More safety by self hold types, Various housings, Manual reset


> Technical Data (standard types)
ratings \ TCO
D10V
D20V
D30V
D40V
function
automatic
manual
self hold
230 V
self hold
120 V
version
normally closed
VDE
rated current at 50 / 60 Hz ( power factor 0.95 / 0.6 )
16 A / 2.5A
(250 V)
19.2 A / 2.5A
(250 V)
16 A / 2.5A
(230 V)
19.2 A / 2.5A
(120 V)
switching cycles
10,000
1,000
10,000
8,000
temperature range Ta (steps in 5 K)
70°C ... 160°C
70°C ... 130°C / 140°C
70°C ... 160°C
UL
rated current at 50 / 60 Hz ( power factor 1.0 / 0.75 )
16 A / 6.3A (250 V)
16 A / - (125 V)
switching cycles
6,000
temperature range Ta (steps in 5 K)
70°C ... 160°C
max. current ( power factor 0.95 )
25 A
switching cycles under max. current
200
tolerance
standard: +/- 5 K
feature of automatic action
1.B, 1.C
2.B, 2.C
2.C.AK
contact resistance
<50 mΩ
hysteresis / reset temperature 1)
30 K +/- 15 K / -
- / < -20°C; < -10°C
-/ < -20°C 2)
degrees of protection provided by
enclosures (EN 60529)
IP00
suitable for use in protection category
I, II
approvals
VDE / ENEC
EN 60730-1 / 2-3 3) / -2-9
UL
UL 873
CSA
C22.2 No. 24 4)
CQC
GB14536.1-1998 / GB14536.10-1996 5)
1) at the Ta (upper and lower) limits the hysteresis could deviate
2) without air ow
3) D12D only/2,5A/max. 140°C
4) different power rating
5) details on request

 

> Terminals
code
used in TCO
illust.
drawing
dimensions (mm)
technical
specification
approvals
standard
D10, D12
D20, D22
D30, D32
D40, D42
 
 
terminals for soldering
CuNi18Zn20 1)
VDE,UL, CSA
A308
D10, D12
D20, D22
D30, D32
D40, D42
 

 

terminals for soldering
bent 90°
CuNi18Zn20 1)
VDE, UL, CSA

1) P types have terminals of CuFe2P material


> Standard Types
TCO
illust.
drawing
dimensions (mm)
technical
specification
approvals
standard
current-time
based 1)
D10V
D12V
 
 
base of thermosetting plastic
VDE,UL, CSA

D10V
D30V
D40V

with
housing G115

D12V
D32V
D42V

with
housing G115
 

 

housings PPS
base of
thermosetting plastic
VDE, UL, CSA
D20V
with housing
G776
D22V
with housing
G776
manual reset

housings PA/PPS
base of
thermosetting plastic
VDE, UL, CSA
D10V
with housing G774
D12V
with housing G774
housings PA/PPS
base of
thermosetting plastic
VDE, UL, CSA

1) For current-time based types (execution D, J, K, L, M, P, R, V) the following information must be provided:


• DC or AC voltage UN in Volts.

Continuous operating current IC in Amps at which the switch must not respond.

Current level I0 in Amps at which the switch must respond.

Response time t0 (in seconds ± tolerance) within which the switch must respond after reaching I0.

Ambient temperatures which could be experienced both in normal operation and after
the switch has responded.

Maximum current in Amps.

* temperature sensitive area.
____________

For special applications version P is available with a very low self heating rate.

Manual reset: The maximum operating force should not exceed 6 N. The control should not be reset before the starting conditions are reached, meaning there should be a satisfactory cooling down time!

Technical data on request.

 

> Characteristics of current vs. self heating and current vs. time

 > Ordering & Marking Example
MIC Ordering Example  D10V12005A308 ]
D10 V 120 05 A308
type execution temperature tolerance terminal code

Marking

D10V type and execution
E country (E=Spain)
12005 response temperature (120°C), tolerance (± 5K)
049
date of manufacture (April 2009)
D12D
type and execution
H
country (H=China)
--123
customised type with drawing number
049
date of manufacture (April 2009)

 

 
CANTHERM
(800) 561-7207 | sales@cantherm.com