CANTHERM
  Heater Protection  
 

< Back to Heater Protection

 PTCR Self-Hold Protector - Temp. Sensitive Only 

Thermal Sensors

A70/A71 PTCR > Online Tech Info
Thermal cutouts and temperature/current cutouts with electrical self-hold switch off after reaching the set temperature or current level. The switch is then held open by a parallel switched heating resistance (PTC) - the cutout will not automatically reset while voltage is applied. It will reset when voltage is removed (i.e. the appliance concerned is disconnected) and the cutout has cooled down.

PDF (Types A10, A11, A50, A51, A70, A71, A72, D14, D54, D73, D74)
   > PDF Tech Info, Schematics and More


Applications Temperature monitoring/regulating/limiting and current limit devices in electrical equipment.

 >Technical Data
Nominal temperature:
70° C. to 160° C.
Tolerance:
+/- 5° C, +/-10° C.
Rated voltage:
120 V/250 V 50-60 Hz, 12VDC
Current rating RES:
16 A / 13 A
Current rating IND:
6.3 A
Max. load with reduced life
RES. 250V 50-60 Hz:
20.0 A
Contact resistance:
<50 m
Characteristics:
Thermal cutout with electrical self-hold
Contact arrangement
normally closed:

Current sensitivity:
All thermostats are temperature sensitive and in the case of high current levels are also current sensitive.
  Push-on, rivet, solders, screw or crimp connectors can be used
Approvals: U.L., CSA, VDE

 

CANTHERM
CANADA (800) 561-7207 | sales@cantherm.com
USA (330) 966-3796 | rmurk@cantherm.com
© 2008, Canadian Thermostats & Control Devices Ltd.