This thermostat operates as a thermal cutout. A thermally sensitive bimetal snap-element with single contacts either opens or closes an electrical circuit by switching at a pre-set response temperature. Reset follows automatically after a considerable drop in temperature.

Applications Single Phase Motors, Generators, Convertors, Transformers, Pumps, Heating Elements, Signal Transmitters, Fire Detectors, Magnets, Relays, Chokes, Coils, Power Supplies, Inverters

Benefits
- Small dimensions
- Shock and vibration tested
- Leadframe version
- Tested for audio, video applications (EN 60065)


> Technical Data
ratings
F11A
F20A / E
F12A1)
F21A / E
F20B / G
F21B / G
version
normally closed
code=2
normally open
code=1
rated current at 250 V 50/60 Hz (power factor 0.95/0.6)
2.0 A / 1.6 A
3.0 A / 2.5 A
3.0 A / 3.0 A
2.0 A / 1.6 A
switching cycles under rated current
7,000
10,000
10,000
7,000
max. current under failure condition at 250 V 50/60 Hz (power factor 0.95)
4.0 A
5.0 A
4.0 A
switching cycles under max. current
3,000
temperature rating Ta (steps in 5 K)
70†C...160†C
70†C...155†C
tolerances
standard:+/- 5 K
feature of automatic action
1.B, 2.B.M, 1.C
2.B, 1.C
contact resistance ( incl. wire of 100 mm )
< 50 mΩ
hysteresis
30 K ± 15 K2
dielectric strength ( standard insulation )
2 kV
shock- / vibration testing ( similar to EN 50155 )
400 m/s2 sine half wave / 100 m/s2 5 Hz ... 2,000 Hz sine
resistances to impregnation
tight against ordinary resins and lacquers
degrees of protection provided by enclosures ( EN 60529 )
IP00
suitable for use in protection category
I, II
approvals
VDE / ENEC
EN 60730-1 / -2-3 3) /-2-9
UL
UL 2111 / UL 873 1)
CSA / cUL
C22.2 No. 77 / C22.2 No. 24 1)
CQC
GB14536.1-1998 / GB14536.10-1996 1)
1) details on request
2) at the Ta (upper and lower) limits the hysteresis could deviate
3) different power rating

 

> Standard wire    length 100 (MIC) | 150 (Cantherm)   ± 10 mm, stripped 6 ± 1 mm
lead

Cantherm
code

MIC
code
temp. max.
operating voltage max.
diameter insulation
cross section diameter1
UL style
black
ACFA
L300
150° C
300 V
1.57 mm
AWG24 / 0.24 mm2
3398
yellow
AEFC
L310
1.80 mm
AWG20 / 0.48 mm2
white
LCFB
L330
200° C
600 V
0.90 mm
AWG24 / 0.24 mm2
3557
white
LEFB
L340
1.26 mm
AWG20 / 0.61 mm2
yellow
 
L400
150° C
300 V
1.40 mm
AWG24 / 0.51 mm
3398
black
ASFA
L410
1.65 mm
AWG20 / 0.81 mm
yellow
DCFB
L430
200° C
300 V
1.21 mm
AWG24 / 0.51 mm
1180
yellow
DEFB
L440
1.51 mm
AWG20 / 0.81 mm
1) AWG24 is recommended

 

> Standard insulation
control type
nc
no
Cantherm code
MIC code
illust.
drawing dimensions (mm)
technicals specification
approvals

F11, F12


F20, F21

A

 
U102 | B
U254
 
 
different dimensions
for F20, F21
shrink cap
potted
VDE,UL, cUL
A B
U106 | F
F11, F12
A
 
U198
U198
 

 

different dimensions
for F20, F21

cap of PPS
potted
VDE, UL, cUL
F20, F21
A
B 
U185
U185

 

> Specific variations     U= insulation   G= Housing
control type
nc
no
Cantherm
code
MIC
code
illust.
drawing dimensions (mm)
technical specification
approvals
F11, F12

A

 
Insulation
None  |  0
 
 
 
not insulated
potted
VDE,UL, cUL

F20, F21

A

B

Insulation
None  |  0
 
not insulated
potted
VDE,UL, cUL, CSA

F11, F12

A

 

Insulation
U112 |  L
U112

different dimensions
for F20, F21
epoxy coated
VDE,UL, cUL
F20, F21
A
B

F20, F21

A

B

Housing
G410 |  6

Leads
A150 |  36
A150 U280
housing of PPS
leadframe leads
grid dimension 5.08
potted
VDE,UL, cUL, CSA

F11, F12

A

 

 

Leads
A800 |  IZA
A800

different dimensions
for F20, F21
not insulated
potted
VDE,UL, cUL
F20, F21
A B

F20, F21

E

G

G700 | B
G700
aluminum housing
thread M4x6
potted

Ta max. 150†C
VDE,UL, cUL, CSA
F11, F12
A
 
G410 | 6

Leads | ACFA
U282
housing of PPS
potted
VDE,UL, cUL

F11, F12

A

 

A150 | 36
A150 U112

different dimensions
for F20, F21
leadframe leads
grid dimension 5.08
epoxy coated
VDE,UL, cUL, CSA
F20, F21
A B
U112 | L

 


The diagram is measured with a thermal control without any insulation in an oil bath.

Attention:
The heating depends on the thermal conduction of the control to the equipment or part which should be protected.

 

 > Ordering & Marking Example
MIC Ordering Example  F20A12005L310100U54 ]
F20 A 120 05 L310 100 U254
type normally closed temperature tolerance
+/-5°C
lead wire white, AWG20 length 100 mm shrink cap insulation

Cantherm Ordering Example  F2012025ACFA06E ]
F20 120 2 5 AC F A 0 6 E
type temperature normally closed tolerance +/-5°C wire leads UL3398 24 AWG lead length
F=6"
color black no insulation

housing - G410 E06

strip .25"

Marking
F20A type (F20 nc)

12005 response temperature (120°C), tolerance (± 5K)

049C date of manufacture (April 2009), country (C = Canada)

 

 
CANTHERM
(800) 561-7207 | sales@cantherm.com
Canadian Thermostats & Control Devices Ltd.