CANTHERM
Thermal Cutouts

 Current Sensitive Thermal Protection For Coils / Windings 

T 10, T 11, T 20, T 21 > Online Tech Info
These thermal cutouts operate by means of a thermally sensitive bimetal snap-element which switches a double electrical contact when reaching a pre-set response temperature. They can be normally open or normally closed. The electrical current being switched flows through the bimetal element, which therefore gives a combination of temperature and current - sensitivity.

PDF (T 10, T 11, T 20, T 21)
    > PDF Tech Info, Schematics and More

Applications Single Phase Motors, Generators, Convertors, Transformers, Pumps, Heating Elements, Signal Transmitters, Fire Detectors, Magnets, Relays, Chokes, Coils, Power Supplies, Inverters

 

> Technical Data
 
T 10
T 11
T 20
T 21
Nominal voltage* 50–60 Hz
250 V
250 V
250 V
250 V
Current rating at cos = 1.0*
2.5 A
2.5 A
10.0 A
16.0 A
Current rating at cos = 0.6*
1.6 A
1.6 A
6.3 A
10.0 A
Max. load
at cos = 1.0
3.8 A
3.8 A
13.0 A
13.0 A
500 V 50 – 60 Hz
380 V 50 – 60 Hz
250 V 50 – 60 Hz
110 V 50 – 60 Hz
60 V DC
42 V DC
6, 12, 24 V DC
min. load 50 m A
3.5 A
4.0 A
6.3 A
10.0 A.
1.0 A
1.2 A
1.5 A
3.5 A
4.0 A
6.3 A
10.0 A
1.0 A
1.2 A
1.5 A


16.0 A
20.0 A
2.5 A
4.8 A
6.3 A



20.0 A
25.0 A
6.3 A
8.0 A
10.0 A

Contact arrangement
Switch operations
at rated current

EI (10.000)

EI (10.000)
1E3 (1.000)
02E2 (200)
Standard
contact resistance**

</= 40 m

</= 40 m
</= 40 m
</= 40 m
Standard
response temperature range
stepped in 5 °C intervals
+50 °C to +180 °C
+50 °C to +180 °C
+50 °C to +160 °C
+50 °C to +160 °C
Standard
tolerance
±3 K ±5 K ±10 K
±5 K ±10 K ±15 K
±2.5 K ±5 K ±10 K
±5 K ±10 K ±15 K
Max. permanent temperature
(standard)
of switch mechanism*
T 180
T 180
T 180
T 180
Standard temperature rating of connecting leads by insulation class and epoxy sealant
(to VDE 0530)
A. E. B. F. H
200 °C max. 10 h
230 °C max. 5 h
A. E. B. F. H
200 °C max. 10 h
230 °C max. 5 h
A. E. B. F.
200 °C max. 10 h
230 °C max. 5 h
A. E. B. F
200 °C max. 10 h
230 °C max. 5 h
Vacuum tightness
Leak rate
standard. ref. P 102
0.133 to 0.0133
bar cm3/sec
standard. ref. P 102
0.133 to 0.0133
bar cm3/sec
standard. ref. P 102
0.133 to 0.0133
bar cm3/sec
standard. ref. P 102
0.133 to 0.0133
bar cm3/sec
Housing material
Coating material
Copper/Beryllium,
Teflon PTFE
stainless steel,
Hard epoxy
rolled bronze,
Hard epoxy
stainless steel,
Hard epoxy
Housing
Insulation options
SHB, SSB, SSH,
UWF, PTFE, SKH, GSS
SHB, SSB, SSH,
UWF, PTFE, SKH,. GSS
HHB, SHB, SSB,
SSH, UWF, VIB
HHB, SHB, SSB,
SSH, UWF, VIB
Cross-section of
the connecting leads standard version
0.25 mm2
0.50 mm2
0.50 mm2
0.75 mm2
Insulation resistance
Dielectric strength
Standard 1250 V 50–60 Hz
P301 2000 V 50–60 Hz
P302 2750 V 50–60 Hz
P303 3750 V 50–60 Hz
P304 4000 V 50–60 Hz
 
T 10
T 11
T 20
T 21
 

* Approved ratings. Further specific values on request, (U, V, B). g Cycle rate 72/h.
** Contact resistance without connections, e. g. leads, wire or terminals.
* The thermostats can be produced with a specific production mark
* (e. g. letter V, U, B). L.S.C.T. 200 A 1/2 hp UL 547.

> Dimensions (Standard)
T 10
T 11
T 21

 

CANTHERM 8415 Mountain Sights Avenue, Montreal (Quebec), H4P 2B8  Canada
 Tel 1-800-561-7207 / (514) 739-3274 | Fax (514) 739-2902 | E-mail sales@cantherm.com

Anglais
 
 © 2007, Canadian Thermostats & Control Devices Ltd.