CANTHERM
  Thermal Cutouts  
 

 Current Sensitive Thermal Protection For Coils / Windings 

T 10, T 11, T 12, T 21, T22 > Online Tech Info
These thermal cutouts operate by means of a thermally sensitive bimetal snap-element which switches a double electrical contact when reaching a pre-set response temperature. They can be normally open or normally closed. The electrical current being switched flows through the bimetal element, which therefore gives a combination of temperature and current - sensitivity.

PDF (T 10, T 11, T 12, T 21, T22)
    > PDF Tech Info, Schematics and More

Applications Single Phase Motors, Generators, Convertors, Transformers, Pumps, Heating Elements, Signal Transmitters, Fire Detectors, Magnets, Relays, Chokes, Coils, Power Supplies, Inverters

 

> Technical Data
ratings
T10A / E
T11A / E
T10B / G
T12A / E
T21A
T21F
T22A
version
normally closed
normally open
normally closed
normally closed
normally open
normally closed
rated current at 250 V 50/60 Hz (power factor 0.95/0.6)
2.5 A / 1.6 A
2.0 A / 1.6 A
6.3 A / 2.5 A
10.0 A / 2.0 A
3.5 A / 2.0 A
20.0 A / -
switching cycles
10,000
max. current at 250 V 50/60 Hz (power factor 0.95)
10.0 A
12.0 A
20.0 A
30.0 A
switching cycles under max. current
300
300
1,000
600
temperature rating Ta (steps in 5 K)
(50) 70°C...180°C 2)
80°C...160°C 5)
tolerances
standard:+/- 5 K1)
feature of automatic action VDE
1.C.M, 2.C, 3.C
1.C, 2.C, 3.C
1.B, 2.C, 3.C
2.B, 1.C, 3.C
contact resistance ( incl. wire of 100 mm )
< 50 mΩ
hysteresis
30 K ± 15 K
dielectric strength ( standard insulation )
2 kV
shock- / vibration testing ( similar to EN 50155 )
400 m/s2 sine half wave / 100 m/s2 5 Hz ... 2,000 Hz sine
-
resistances to impregnation
tight against ordinary resins and lacquers
degrees of protection provided by enclosures ( EN 60529 )
IP00
suitable for use in protection category
I, II
approvals
VDE
EN 60730-1 / -2-2 / -2-3 3) /-2-9
UL
UL 2111 / UL 873 4)
CSA / cUL
C22.2 No. 77 / C22.2 No. 24 4)
1) available with ± 3K tolerances and smaller hysteresis
2) T10 max. Ta 160°C
3) different power rating
4) on request
5) if T22 used as thermal motor protector up to 180°C

 

> Standard wire ( length 100 ± 10 mm, stripped 6 ± 1 mm )
lead
code
temp. max.
operating voltage max.
diameter insulation
cross section diameter2)
UL style
stranded
white
L300
150° C
300 V
1.57 mm
AWG24 / 0.24 mm2
3398
L320
1.80 mm
AWG20 / 0.48 mm2
L320 1)
2.15 mm
AWG18 / 0.96 mm2
L330
200° C
600 V
0.90 mm
AWG24 / 0.24 mm2
2557
L340
1.26 mm
AWG20 / 0.61 mm2
L350 1)
1.50 mm
AWG18 / 0.96 mm2
solid
yellow
L400
150° C
300 V
1.40 mm
AWG24 / 0.51 mm
3398
L410
1.65 mm
AWG20 / 0.81 mm
L430
200° C
300 V
1.21 mm
AWG24 / 0.51 mm
1332
L440
1.51 mm
AWG20 / 0.81 mm
1) T21 / T22 only
2) for T10 / T11 / T12 AWG20 recommended

 

> Standard insulation
control type
nc
no
code
illust.
drawing dimensions (mm)
technicals specification
approvals
T10

A

B
U250
 
 
different dimensions
for T21/ T22
shrink cap
potted
VDE,UL, cUL
T11, T12
A
 

T21

A

F

U256
T22
A  
T10
A
 B
U174
 

 

cap of PPS
potted
VDE, UL, cUL
T11, T12
A
 

 

> Specific variations
control type
nc
no
code
illust.
drawing dimensions (mm)
technicals specification
approvals
T10

A

B
 
 
 
type T11, T12 illustrated
no insulation
potted
VDE,UL
cUL, CSA
T11, T12
A
 
T10
A
 B
U112
 

 

coated

Ta max. 160°C
VDE, UL, cUL
T10
T11, T12
A
 
T11, T12
A
 
A334
PPS Cap
PCB thru-hole
Terminals
5.08mm (0.2")
spacing
VDE, UL, cUL
T11, T12
A
 
A334 U314
PPS Cap
PCB thru-hole
Terminals
5.08mm (0.2")
spacing
VDE, UL, cUL
T11, T12
A
 
A334 U315
PPS cap
PCB connector
grid dimension 5.08
VDE, UL, cUL
T10
A
B
U293
PPS housing
potted
VDE, UL, cUL
T11, T12
A
 
T10
E
G
G502
Aluminum housing
anodized black M4x6
potted

Ta max. 150°C
VDE, UL, cUL
T11, T12
E
 

T21

T22

A

A

F

 

 
No insulation
potted
VDE, UL, cUL, CSA

T21

T22

A

A

F

 

U112
Epoxy coated
Ta Max / 60°C
VDE, UL, cUL

 

> Self-Heating by Current

The diagram is measured with a thermal control without any insulation in an oil bath.

Attention:
The heating depends on the thermal conduction of the control to the equipment or part which should be protected.
 
> Ordering & Marking Example

 

CANTHERM
CANADA (800) 561-7207 | sales@cantherm.com
USA (330) 966-3796 | rmurk@cantherm.com
© 2008, Canadian Thermostats & Control Devices Ltd.