 Current Sensitive Thermal Protection For Coils / Windings  PDF

T 10, T 11, T 12, T 21, T22 > Online Tech Info
These thermal cutouts operate by means of a thermally sensitive bimetal snap-element which switches a double electrical contact when reaching a pre-set response temperature. They can be normally open or normally closed. The electrical current being switched flows through the bimetal element, which therefore gives a combination of temperature and current - sensitivity.

Applications Single Phase Motors, Generators, Convertors, Transformers, Pumps, Heating Elements, Signal Transmitters, Fire Detectors, Magnets, Relays, Chokes, Coils, Power Supplies, Inverters

 

> Technical Data
ratings
T10A / E
T11A / E
T12A / E
T22A
T10B / G
T22B 1)
version
normally closed
code=2
normally open
code=1
rated current at 250 V 50/60 Hz (power factor 0.95/0.6)
2.5 A / 1.6 A
6.3 A / 2.5 A
20.0 A / 3.0 A
2.0 A / 1.6 A
3.5 A / 2.0 A
switching cycles under rated current
10,000
max. current under failure condition at 250 V 50/60 Hz (power factor 0.95)
10.0 A
12.0 A
30.0 A
10.0 A
20.0 A
switching cycles under max. current
300
600
300
1,000
temperature rating Ta (steps in 5 K)
(50) 70°C...180°C 2)
80°C...160°C 3)
tolerances
standard:+/- 5 K
feature of automatic action
1.C.M, 2.C
2.B, 1.C, 3.C
1.B, 2.C
contact resistance ( incl. wire of 100 mm )
< 50 mΩ
hysteresis
30 K ± 15 K 4) 5)
dielectric strength ( standard insulation )
2 kV
shock / vibration testing ( similar to EN 50155 )
400 m/s2 sine half wave / 100 m/s2 5 Hz ... 2,000 Hz sine
resistances to impregnation
tight against ordinary resins and lacquers
degrees of protection provided by enclosures ( EN 60529 )
IP00
suitable for use in protection category
I, II
approvals
VDE / ENEC
EN 60730-1 / -2-3 6) /-2-9
UL
UL 2111 / UL 873 1)
-
CSA / cUL
C22.2 No. 77 / C22.2 No. 24 1)
-
-
CQC
GB14536.1-1998 / GB14536.10-1996 1)
1) details on request
2) T10 max. Ta 160°C
3) approval to EN60730-2-2 up to 180°C
4) T10 available with ± 3K tolerances and smaller hysteresist
5) at the Ta (upper and lower) limits the hysteresis could deviate
6) different power rating

 

> Standard wire ( length 100 ± 10 mm, stripped 6 ± 1 mm )
lead
Cantherm
code
MIC
code
temp. max.
operating voltage max.
diameter insulation
cross section diameter2)
UL style
black
ACDA
L300
150° C
300 V
1.57 mm
AWG24 / 0.24 mm2
3398
yellow
AEDC
L320
1.80 mm
AWG20 / 0.48 mm2
black
AFDA
L320 1)
2.15 mm
AWG18 / 0.96 mm2
white
LCDB
L330
200° C
600 V
0.90 mm
AWG24 / 0.24 mm2
3557
white
LEDB
L340
1.26 mm
AWG20 / 0.61 mm2
white
LFDB
L350 1)
1.50 mm
AWG18 / 0.96 mm2
yellow
 
L400
150° C
300 V
1.40 mm
AWG24 / 0.51 mm
3398
black
ASDA
L410
1.65 mm
AWG20 / 0.81 mm
white
DFDB
L430
200° C
300 V
1.21 mm
AWG24 / 0.51 mm
1180
white
DEDB
L440
1.51 mm
AWG20 / 0.81 mm

1) T22 only
2)
for T12/T11 AWG20 and for T10 AWG24 is recommended

 

> Standard insulation
control type
nc
no
Cantherm
code
MIC
code
illust.
drawing dimensions (mm)
technicals specification
approvals
T10

A

B
U102 | B
U250
 
 
different dimensions
for T22
shrink cap
potted
VDE,UL, cUL
T11, T12
A
 
U106 | F

T22

A

B

U103 | C
U256
U107 | G
T10
A
 B
U153 | V
U174
 

 

cap of PPS
potted
VDE, UL, cUL
T11, T12
A
 
U174 | O

 

> Specific variations
control type
nc
no
Cantherm
code
MIC
code
illust.
drawing dimensions (mm)
technicals specification
approvals
T10

A

B

Insulation

0

 
 
 
type T11, T12 illustrated
no insulation
potted
VDE,UL
cUL, CSA
T11, T12
A
 
T10
A
 B

Insulation

U112 | L

U112
 

 

coated

Ta max. 160°C
VDE, UL, cUL
T11, T12
A
 
T11, T12
A
 

Wire Type

A334 | 6

A334
no insulation
PCB connector
grid dim. 5.08
VDE, UL, cUL
T11, T12
A
 

Insulation

U314 | 4

A334 U314
cap of PPS
PCB connector
grid dim. 5.08
VDE, UL, cUL
T11, T12
A
 

Insulation

U315 | 5

A334 U315
cap of PPS
PCB connector
grid dimension 5.08
VDE, UL, cUL
T10
A
B

Insulation

U293 | 2

U293
housing of PPS
potted
VDE, UL, cUL
T11, T12
A
 
T10
E
G

Housing

G502 | E

G502
potted
aluminum housing
anodized black M4x6


Ta max. 150°C
VDE, UL, cUL
T11, T12
E
 

T22

A

B

Insulation

0

 
No insulation
potted
VDE, UL, cUL, CSA

T22

A

B

Insulation

U112 | L

U112
coated
Ta Max / 60°C
VDE, UL, cUL

 

> Heating by Current



The characteristic curves are measured with a thermal control without any insulation in an oil bath.

Attention:
The heating depends on the thermal conduction of the control to the equipment or part which should be protected.

 > Ordering & Marking Example
MIC Ordering Example  T11A12005L310100U250 ]
T11 A 120 05 L310 100 U250
type normally closed temperature tolerance
+/-5°C
lead wire white, AWG20 length 100 mm shrink cap insulation

Cantherm Ordering Example  T1112025AEDCB0E ]
T11 120 2 5 AE D C B 0 E
type temperature normally closed tolerance +/-5°C lead wire
UL3398
20 AWG
lead length
D=4"
yellow insulation
U102

housing - none

strip length .25"

Marking
T11A type (T11 nc)

12005 response temperature (120°C), tolerance (± 5K)

049C date of manufacture (April 2009), country (C = Canada)

> Site : eRGB 
CANTHERM
(800) 561-7207 | sales@cantherm.com