H101>
Online Tech Info
H101(710°C
/ 1,328°F)
H101
>
PDF Tech Info, Schematics and More
Features
1. Unique fuse of 710°C/550°C.
2. External dimensions are the same for all H101 models.
3. The fuse is housed in a ceramic cylinder case.
Precautions
for handling
1. When the current exceeds the rated value, it will
activate at a lower temperature than the fusing preset
temperature. Check once again that the current is
not exceeding the switching capacity.
2. Unexpected force or shock during transportation
or mounting may cause breakage of the temperature
fuse. Furthermore, if the ambient temperature goes
up, it may lead to an accidental fusing at a lower
temperature. So, be careful regarding the ambient
temperature.
3. Keep the temperature sensor (protection tube) horizontal
or pointing downward (lead wire will be at the
top) when in use. If it is used with the temperature
sensor up, it may cause a malfunction.
4. Do not use in an environment where vibration or
shock is constantly applied.
5. Watch for other heat sources, and try to avoid
thermal interference. Be careful of fuse malfunction
due to unexpected other heat sources. |