D10, D20, D30, D40

Home/D10, D20, D30, D40
Home > Products > D10, D20, D30, D40
image

Appareils Électroménagers. Électronique, Radiateur Soufflant, Industrie Automobile.

Protection Pour Chaufferettes

Appareils Électroménagers. Électronique, Radiateur Soufflant, Industrie Automobile.

D10, D20, D30, D40

Applications

Household appliances, Electronics, Fan Heaters, Automotive Industry

Benefits

More safety by self hold types, Various housings, Manual reset

Technical Data (standard types)

ratings \ TCOD10VD20VD30VD40V
functionautomaticmanualself hold
230 V
self hold
120 V
versionnormally closed
VDErated current at 50 / 60 Hz ( power factor 0.95 / 0.6 )16 A / 2.5A
(250 V)
19.2 A / 2.5A
(250 V)
16 A / 2.5A
(230 V)
19.2 A / 2.5A
(120 V)
switching cycles10,0001,00010,0008,000
temperature range Ta (steps in 5 K)70°C … 160°C70°C … 130°C / 140°C70°C … 160°C
ULrated current at 50 / 60 Hz ( power factor 1.0 / 0.75 )16 A / 6.3A (250 V)16 A / – (125 V)
switching cycles6,000
temperature range Ta (steps in 5 K)70°C … 160°C
max. current at 250 V 50/60Hz( power factor 0.95 )25 A
switching cycles under max. current200
tolerancestandard: +/- 5 K
feature of automatic action1.B, 1.C2.B, 2.C2.C.AK
contact resistance<50 mΩ
hysteresis / reset temperature 1)30 K +/- 15 K / –– / < -20°C; < -10°C-/ < -20°C 2)
degrees of protection provided by
enclosures (EN 60529)
   IP00
suitable for use in protection categoryI, II
approvalsVDE / ENECEN 60730-1 / 2-3 3) / -2-9
ULUL 873
CSAC22.2 No. 24 3)
CQCGB14536.1-1998 / GB14536.10-1996 4)
1) at the Ta (upper and lower) limits the hysteresis could deviate
2) without air Åow
3) D12D only/2,5A/max. 140°C
4) different power rating
5) details on request

Terminals

codeused in TCOillust.drawing
dimensions (mm)
technical
specification
approvals
standardD10, D12
D20, D22
D30, D32
D40, D42
terminals for soldering
CuNi18Zn20 1)
VDE,UL, CSA
A308D10, D12
D20, D22
D30, D32
D40, D42
terminals for soldering
bent 90°
CuNi18Zn20 1)
VDE, UL, CSA

Standard Types

TCOillust.drawing
dimensions (mm)
technical
specification
approvals
standardcurrent-time
based 1)
D10VD12Vbase of thermosetting plasticVDE,UL, CSA
D10V
D30V
D40V 

with
housing G115
D12V
D32V
D42V 

with
housing G115
housings PPS
base of
thermosetting plastic
VDE, UL, CSA
D20V
with housing
G776
D22V
with housing
G776
manual reset

housings PA/PPS
base of
thermosetting plastic

VDE, UL, CSA
D10V
with housing G774
D12V
with housing
G774
housings PA/PPS
base of
thermosetting plastic
VDE, UL, CSA

1) For current-time based types (execution D, J, K, L, M, P, R, V) the following information must be provided:

• DC or AC voltage UN in Volts.

• Continuous operating current Ic in Amps at which the switch must not respond.

• Current level I0 in Amps at which the switch must respond.

• Response time t0 (in seconds ± tolerance) within which the switch must respond after reaching I0.

• Ambient temperatures which could be experienced both in normal operation and in switching conditions.

• Maximum current in Amps.

* temperaturesensitive area.
____________

• For special applications version P is available with a very low self heating rate.

• Manual reset: The maximum operating force should not exceed 6 N. The control should not be reset before the starting conditions are reached, meaning there should be a satisfactory cooling down time!

Technical data on request.

Characteristics of current vs. self heating and current vs. time

Ordering & Marking Example

MIC Ordering Example   [ D10V12005A308 ]
D10V12005A308
typeexecutiontemperaturetoleranceterminal code

 

Marking
D10V type and execution
E  country (E=Spain)
12005  response temperature (120°C), tolerance (± 5K)
049  date of manufacture (April 2009)
D12D  type and execution
H  country (H=China)
–123  customised type with drawing number
049  date of manufacture (April 2009)