
Benefits
More safety by self hold types, Various housings, Manual reset
Technical Data (standard types)
ratings \ TCO | D10V | D20V | D30V | D40V | |
function | automatic | manual | self hold 230 V |
self hold 120 V |
|
version | normally closed | ||||
VDE | rated current at 50 / 60 Hz ( power factor 0.95 / 0.6 ) | 16 A / 2.5A (250 V) |
19.2 A / 2.5A (250 V) |
16 A / 2.5A (230 V) |
19.2 A / 2.5A (120 V) |
switching cycles | 10,000 | 1,000 | 10,000 | 8,000 | |
temperature range Ta (steps in 5 K) | 70°C … 160°C | 70°C … 130°C / 140°C | 70°C … 160°C | ||
UL | rated current at 50 / 60 Hz ( power factor 1.0 / 0.75 ) | 16 A / 6.3A (250 V) | 16 A / – (125 V) | ||
switching cycles | 6,000 | ||||
temperature range Ta (steps in 5 K) | 70°C … 160°C | ||||
max. current at 250 V 50/60Hz( power factor 0.95 ) | 25 A | ||||
switching cycles under max. current | 200 | ||||
tolerance | standard: +/- 5 K | ||||
feature of automatic action | 1.B, 1.C | 2.B, 2.C | 2.C.AK | ||
contact resistance | <50 mΩ | ||||
hysteresis / reset temperature 1) | 30 K +/- 15 K / – | – / < -20°C; < -10°C | -/ < -20°C 2) | ||
degrees of protection provided by enclosures (EN 60529) |
IP00 | ||||
suitable for use in protection category | I, II | ||||
approvals | VDE / ENEC | EN 60730-1 / 2-3 3) / -2-9 | |||
UL | UL 873 | ||||
CSA | C22.2 No. 24 3) | ||||
CQC | GB14536.1-1998 / GB14536.10-1996 4) | ||||
1) at the Ta (upper and lower) limits the hysteresis could deviate 2) without air Åow 3) D12D only/2,5A/max. 140°C 4) different power rating 5) details on request |
Terminals
code | used in TCO | illust. | drawing dimensions (mm) |
technical specification |
approvals | |||||
standard | D10, D12 D20, D22 D30, D32 D40, D42 |
![]() |
![]() |
terminals for soldering CuNi18Zn20 1) |
VDE,UL, CSA | |||||
A308 | D10, D12 D20, D22 D30, D32 D40, D42 |
![]() |
![]() |
terminals for soldering bent 90° CuNi18Zn20 1) |
VDE, UL, CSA |
Standard Types
TCO | illust. | drawing dimensions (mm) |
technical specification |
approvals | ||||||
standard | current-time based 1) |
|||||||||
D10V | D12V | ![]() |
![]() |
base of thermosetting plastic | VDE,UL, CSA | |||||
D10V D30V D40V with housing G115 |
D12V D32V D42V with housing G115 |
![]() |
![]() |
housings PPS base of thermosetting plastic |
VDE, UL, CSA | |||||
D20V with housing G776 |
D22V with housing G776 |
![]() |
![]() |
manual reset
housings PA/PPS |
VDE, UL, CSA | |||||
D10V with housing G774 |
D12V with housing G774 |
![]() |
![]() |
housings PA/PPS base of thermosetting plastic |
VDE, UL, CSA |
1) For current-time based types (execution D, J, K, L, M, P, R, V) the following information must be provided:
|
Characteristics of current vs. self heating and current vs. time

Ordering & Marking Example
|